15 — FREQUENTLY ASKED
GRP-to-lead bay roof questions
Why was the GRP removed rather than covered with lead?
The project involved reconstruction of the roof build-up beneath the existing coverings. Removing the GRP allowed the underlying layers to be opened, assessed and rebuilt before installing the new lead weathering.
What is a warm roof?
In broad terms, a warm or compact roof arrangement places insulation above the principal structural support so that the supporting construction remains on the warmer side of the insulation. The complete build-up still requires appropriate design of vapour control and junctions.
Does a warm roof eliminate condensation automatically?
No. Condensation risk depends on the complete construction, internal moisture conditions, insulation continuity, vapour-control strategy and junction detailing. The term “warm roof” alone is not a guarantee of performance.
What lead code was used on these bay roofs?
Code 5 rolled lead sheet was used on this project. Other bay roofs should be specified according to their own dimensions, geometry and exposure.
Why was stainless steel incorporated into the detail?
A bespoke stainless-steel tray and custom restraint were used at particular areas of this project to provide a robust supporting solution within the exposed and geometrically difficult interfaces.
Can The Lead Lads undertake projects outside Yorkshire?
Yes. Suitable specialist projects can be considered further afield. This Scottish Borders project was initially assessed using clear photographs, dimensions and project information before the works were undertaken on site.